Good product, good way

Dry-type iron core shunt reactor

In the power system, the dry-type iron core shunt reactor is used to compensate the capacitive current of the line, and to suppress the increase of the power frequency voltage and operating overvoltage at the end of the line caused by the capacitive reactive power of the line when the transmission line is lightly loaded.

Description

Model Number:dry type transformer
Usage:Electronic, Power/ Electric Power Transmission
Phase:Three
Coil Structure:Toroidal
Frequency:50/60Hz
Material:Copper Winding
Application:Industrial Power Supplies
Cooling Method:ANAF

Definition

In the power system, the dry-type iron core shunt reactor is used to compensate the capacitive current of the line, and to suppress the increase of the power frequency voltage and operating overvoltage at the end of the line caused by the capacitive reactive power of the line when the transmission line is lightly loaded. At the same time, the connection of the parallel reactor can reduce the latent supply current during the system ground fault, which is beneficial to eliminate the self-excitation of the generator.

Features

1.The iron core adopts special design compression and special techniques to reduce noise effectively ;

2.The coils and iron cores are cast with vacuum epoxy. The products are characterized by high mechanical strength, strong short-circuit resistance and low temperature rise.

3.Product design fully takes into account the effects of higher harmonic of the network;

4.Low loss, energy-saving effect, maintenance-free;

5.Good moisture resistance, suitable for operation in high humidity and other harsh environments.

Function and role

1. Using silicon steel sheet as the magnetic medium

2. The magnetic flux uses the iron core as the magnetically conductive circuit

3. No electromagnetic pollution to the surrounding environment

4. Coil insulation heat resistance grade can be f grade, h grade, etc.

5. Low vibration and low noise during exercise.

Installation method

There are two types of dry-type hollow reactor installations: horizontal and vertical. The angles of the input and output terminals are 0 °, 90 °, and 180 °. If the user has special requirements for the direction of the output terminals, they can be specified when ordering. When installing a hollow reactor, the minimum net magnetic field space distance of the reactor to other metal parts should be guaranteed. 的 The static space distance of metal parts that are not visible and form a closed loop should be increased.

Image

 

 

 

Product knowledge

No Related Product knowledge!

Good Methods

No Related Good Methods!